UT3335 Differential scanning Calorimeter, Oxidative Induction Time test (OIT)

Oxidation induction time or OIT is a standardized test performed in a DSC ( Differential scanning Calorimeter) which measures the level of thermal stabilization of the material tested. The time between melting and the onset of decomposition in isothermal conditions is measured. The atmosphere is nitrogen up to melting and then oxygen. The typical temperature is 190-220 °C.


Oit.png


UT3335 Differential scanning calorimeter is one kind of thermal analysis method instrument, under controlled temperature, check the relation of temperature with the rate differential input in test sample and reference articles.  The curve recorded is DSC curve, heat flow rate dH/dt is Y-axis, temperature T or time t is X-axis, can measure various kind of thermodynamics and kinetic parameter, like specific heat capacity, reaction heat, heat of transformation, phase diagram, reaction rate, cystallization rate, sample purity etc.,  with wide temperature range (-100~800℃), high resolutions, less sample using. Used to test inorganic material, organic compounds, pharmaceutical analysis etc.,  can be used to do Oxidative Induction Time test, heat stability, glass transition temperature, melting point, cold crystallization, crystallization, phase transition,  etc.,         

 


Conform to standard EN 728.   ISO 11357-6, ASTM D3417.     



The measuring range

0~±500mW

Temperature range

Room temperature ~ 800℃
  *  -30℃~800℃   semiconductor refrigeration  (optional)
  *  -100℃~800℃ Liquid   nitrogen refrigeration (optional)

Temperature rising rate

1~80℃/min

Temperature   falling rate

1 ~ 20 ℃ / min

Temperature resolution

0.1℃

Temperature   0.1 ℃ accuracy

±0.1℃

Temperature   repeatability

±0.1℃

DSC noise

0.01μW

DSC   resolution

0.01μW

DSC   accuracy

0.1μW

DSC   sensitivity

0.1μW

Temperature   control mode

Rising temp., constant temp., falling temp. (automatic control)

Curve   scanning

Rising temperature scanning,   
   cooling scan (Optional)

Atmosphere   control

Static or dynamic atmosphere

Display

Large LCD screen Engligh

Power

220V, 50HZ

Offer standard material (indium, tin, lead), user   can calibrate the temperature by self.


BS EN 728

Plastics piping and ducting systems. Polyolefin pipes and fittings. Determination of oxidation induction time.


ISO 11357-6:2018
Plastics -- Differential scanning calorimetry (DSC) -- Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)


ASTM D3417
Standard Test Method for Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC)

      
DSC Oxidative Induction Time test sample install video
  
Differential scanning Calorimeter, Oxidative Induction Time test (OIT) operation video 1
  
Differential scanning Calorimeter, Oxidative Induction Time test (OIT) operation video 2