UT2040 Hot and cold water cycle testing machine is suitable for all kinds of plastic pipes and pipe fittings according to the requirements of the standard after the assembly of the pipeline system test, the pipeline system withstands a certain internal pressure, in the specified time cold and hot temperature alternate changes, after completing the specified number of tests, check the leakage and rupture of pipes and pipe fittings.
The test is a long-term stability test, a set of plastic pipe system specimen test requires 5000 cycles of hot and cold water, each hot and cold water cycle is 30 minutes (15 minutes of cold water, 15 minutes of hot water), so the test must ensure long-term reliable operation, stable performance.
The instrument is mainly composed of cold water exchange execution module, hot water exchange execution module, specimen room, industrial chiller and other major parts; Its appearance is beautiful, the module is structured, the technology is advanced, the performance is stable, the quality is reliable, and the operation is simple.
Standards:
ISO 10508:2006 Plastics piping systems for hot and cold water installations — Guidance for classification and design.
Pressure control range | 0.4~1.76Mpa |
Pressure control accuracy | ±0.02MPa |
Test Working stations | 6 working stations independent |
Max. working area | 6200mm2 (2×Φ63), mean if at same time do test for max. diameter pipe 63mm, can do 2 pcs. The remain 4 stations can do small pipe like 16mm etc., At the same time can do 6 pcs 16mm pipes test. |
Hot and cold water cycle time | Set arbitrarily between 600s and 1800s |
Alternating hot and cold water times | ≤60s |
Number of cycles | 0 ~ 100000 times any setting |
The maximum straight length of the specimen | 3700mm |
Display mode | Touch screen display |
Control mode | PLC control |
velocity of flow | >0.9m/s |
Water source water quality | Pure, deionized or demineralized water |
Automatic hydration pressure | >0.05MPa |
The temperature display indicates the error | ±0.2℃ |
Sample inlet outlet temperature difference | <2℃ |
Cooling water tank: | |
Temperature control range | 10°C~ room temperature (room temperature>20°C) |
Temperature control accuracy | The setpoint ± 0.5°C |
Temperature uniformity | ±0.5℃ |
volume | ≥500L |
Hot water tank: | |
Temperature control range | room temperature ~ 95°C |
Temperature control accuracy | The setpoint ± 0.5°C |
Temperature uniformity | ±0.5℃ |
volume | ≥500L |
power supply | 380(1-15%)V~380(1+10%)V 50Hz 25kW |
Dimensions | 4500mm*3000mm*2100mm |
Installation dimensions | 6000mm*4000mm*3000mm |
Total weight | 3210kg |
Item | Quantity |
1, Frame | |
Stainless steel inverter pump | 1 set |
Stainless steel circulation pump | 3 set |
Inverter speed controller | 1 set |
Pressure Transmitter | 1 set |
PLC | 1 set |
Human Machine Interface (HMI) | 1 pc |
Insulated stainless steel cold water tank (304) | 1 pc |
Insulation Stainless Steel Hot Water Tank (304) | 1 set |
Stainless Steel Temperature Sensor (304) | 4 pcs |
Refrigeration unit (industrial chiller) | 1 set |
Heater (stainless steel 304) | 1 set |
Pressure display table | 1 set |
Specimen room | 1 set |
High pressure pneumatic control valve | 4 set |
Water treatment plants | 1 set |
Pump | 1 set |
Pre-tensioned loading device | 1 set |
Documents (Manual, packing list, certificate) | |
ISO 10508:2006