The pipe opacity tester can be used to determine the impermeability determination of plastic pipes and fittings (showing results as a percentage). The instrument is controlled by an industrial touch screen and operated by a touch screen. It has the function of automatic analysis, recording, storage, display. The series of products are widely used in scientific research institutions, universities, quality inspection departments, production enterprises.
Conform to standard: ISO 7686:2005 Plastics pipes and fittings — Determination of opacity
Feature:
1, can be tested at the same time four specimens, if less than four specimens can also be selected to test;
2, the use of industrial-grade anti-jamming ability of the touch screen as a human-computer interaction interface, the operation process is simple and convenient;
3, light-flux acquisition system using high-precision optical collectors and at least 24 bits of module-digital conversion circuit.
4, with four specimens, 12 measuring points automatic ally, positioning, tracking, mobile test function, that is, to achieve fully automatic measurement.
5, with automatic analysis, recording, storage, display functions.
6, the instrument structure is reasonable, stable performance, high efficiency, energy saving, simple operation and easy maintenance.
Light source filter permeability chart
Control mode | ARM core board control, test process fully automatic, touch screen operation, display |
Pipe diameter range | Diameter 16 to 40mm |
light flux acquisition system | the use of high-precision optical collector and 24-bit module conversion circuit |
optical wavelength | 545nm x 5nm, led energy-saving standard light source |
light flux resolution | ±0.1% |
light flux measurement error | ±0.5% |
Grating | 5 kinds of specifications: 16, 20, 25, 32, 40 |
automatic in/out speed | 384mm/min |
automatic in/out of the position moving distance | 160mm±0.5mm |
sample tracking system movement speed | 420mm/min |
sample tracking system positioning accuracy | ±0.1mm |
* The use of grating automatic replacement system, with automatic control of grating movement according to the sample specifications, automatic positioning, automatic tracking of the prototype function. * The specimen frame has automatic positioning of the specimen, to ensure that the specimen surface and incident light vertical function. * With a continuous completion of the same pipe sample of 4 specimens (3 measuring points per specimen) automatic identification, positioning, tracking, mobile test function. * Supporting a set of 540nm enzyme label analyzer, including a light transmission rate of 3.16%, 10%, 31.6%, 63% of the standard substances each piece, for the calibration of the instrument. |
ISO 7686:2005 Plastics pipes and fittings — Determination of opacity