- Universal testing machine
- Fixtures
- Medical/Biomedical device
- Vehicles motorcycle
- Compression/Flexural test
- Hardness tester
- Impact testing machine
- Torsion testing machine
- Abrasion & wear tester
- Plastic & Pipe testing
- Tensiometer / Goniometer
- Erichsen cupping tester
- Other Testing Equipment
- Grinding & polishing machine
- Introduction
- Specification
- Accessories
- Standard
- LEAFLET & VIDEO
- Contact Us
Surgical Suture needle toughness tester is a new product developed by our company. It is used to describe the surface structure of processed parts. It is suitable for testing in workshop verification station, laboratory, metrology room and other environments. It is also suitable for on-site measurement. It can evaluate five measurement types: Roughness profile, Waviness profile, Primary profile, Abbott curve and Motif. The measurement parameters include China, Japan, the United States, Germany and a variety of ISO standards. It has user-friendly software interface and operation habits. Wireless WiFi communication allows the operator to remotely control and use it more conveniently. We have designed the software to record the configuration under different operation scenarios. There is no need to make cumbersome settings when measuring different workpieces. We only need to select the configuration and press one key to measure. For details such as operation, please read the following instructions patiently.
Test Result: the surface toughness Ra value is less than 0.8um.
Product Features
High precision large stroke guide rail, length up to 50mm
Sensor range ± 500 μ m
Using Pad as an Operator, which is convenient to carry and comfortable to operate
Wireless WiFi communication, remote operation, easy to use
Network connection communication can automatically switch with WiFi communication, which can achieve faster data transmission in the workshop where it is not convenient to use wireless equipment
The parameters are comprehensive, including 5 measurement types and a variety of national standards
Measure WITH or WITHOUT a guide head, and the measurement of small values WITHOUT a guide head is also very accurate
The stylus can be directly replaced,and the replacement operation is convenient, which can realize the measurement in different scenes.
The sensor can be switched vertically or in the same direction with the guide rail at will, so the measurement of deep grooves can be made from the side without being limited by the depth of the stylus and groove
Metric and Imperial system available
Chinese interface and English interface available
The data storage is convenient. The storage path can be directly changed to the USB flash disk or SD card inserted on the Pad. The CSV data format makes the data more convenient to use without the upper limit of data storage
The analysis algorithm including multiple filter methods can be matched at will to meet the requirements
It supports automatic multiple calibration of standard blocks, so that the calibration error is greatly reduced
Model | SSR300+ | ||||
Range | X direction | 50mm | |||
Z direction | ±500μm | ||||
Resolution | X direction | 0.0016μm/±50μm -0.016μm/±500μm | |||
Driver | Straightness | 1μm/50mm | |||
Analysis
algorithm | Corresponding Standard | JIS-82、JIS-87、JIS-94、JIS-01、JIS-13、 ISO-84、ISO-97、DIN-90、ASME-95、 GB-14 | |||
Parameters | Roughness profile | Ra75、Rq、Rp、Rv、Rc、Rt、S、R3z、 PPI、Ra、Rsk、Rku、Ry、Sm、RΔa、 RΔq、Rz、Pc、Rλa、Rλq、lr、RSm、 Rz94、RPc、RS、Rz.I、Rpm、HSC | |||
Waviness profile | WCA、WCC-q、WCC-p、WCC-v、 WCC-m、WCC-Sm、WCA、WC-q、 WC-p、WC-v、WCM、WC-Sm、 WC-t、Wa、Wq、Wsk、Wku、Wp、 Wv、Wz、Wc、Wt、WSm、WΔq、 WPc | ||||
Primary profile | Rsk、Rku、Rmax、Sm、Δa、Δq、Rz、 λa、λq、lr、TILT A、AVH、Hmax、 Hmin、AREA、Rz.J、Pa、Pq、Psk、 Pku、Pp、Pv、Pc.I、Pt、PSm、PΔq、 PPc、Pc | ||||
Abbott curve | Rk、Rpk、Rvk、Mr1、Mr2、V0、K、 A1、A2 | ||||
Motif | NCRX、AR、R、Rx、NR、CPM、SR、 SAR、AW、W、Wx、Wte、NW、SW、 SAW、Rke、Rpke、Rvke、Mr1、Mr2、 V0、K | ||||
Evaluation curve | Roughness profile、Waviness profile、 Primary profile、Abbott curve、Motif | ||||
Characteristic curve | Abbott curve (Rmr(c)、Rmr2(c)、Rδc(c)、 tp(c)、tp2(c)、Htp(c))、 Amplitude frequency analysis curve、amplitude distribution curve | ||||
Form remove | global, first half, second half, center, 2 points, curve | ||||
Filter type | Gaussian、FFT、PC、DP、2RC | ||||
Filter wave length | λs | 0、2.5、8、25μm | |||
λc | 0.08、0.25、0.8、2.5、8mm | ||||
λf | 0.8、2.5、8、25mm | ||||
Evaluation length | Sampling length × number of samples (sampling length has standard mode and custom mode) | ||||
Measurement speed | 0.05mm/s、0.10mm/s、0.50mm/s、 1.00mm/s、2.00mm/s | ||||
Return speed | 0.05mm/s、0.10mm/s、0.50mm/s、 1.00mm/s、2.00mm/s | ||||
SENSOR | Mode | Standard universal type | |||
Sensor mode | Differential inductance | ||||
Range | ±500μm | ||||
Stylus | 5μmR diamond 90° | ||||
Contact Force Of the Stylus | Adjustable 4~ 7.5mN | ||||
OPERATOR | Display part | 10-inch color IPS touch screen | |||
Data output | TF card/U disk/WIFI printing/PDF file | ||||
Corresponding language | Chinese/English | ||||
Size and quality | Power supply | AC220V±10% Built-in rechargeable battery (AC adapter charging) 8 hours charging time | |||
Power consumption | About 30VA (800 times can be measured after fully charged) | ||||
Quality | Dry weight 4Kg 8Kg package included | ||||
Size setting | Actuator 80(W)*392(L)*180(H) Operator 245(W)*162(D)*68(H) |
Host Actuator | 1 |
Sensor | 1 |
10-inch Pad Operator | 1 |
Host charger | 1 |
Pad charger | 1 |
Standard stylus | 1 |
Roughness standard test block | 1 |
Product certificate | 1 |
Product manual | 1 |
Warranty card | 1 |
Data communication line | 1 |
Host waterproof box | 1 |
Random tools | Allen wrench (1.5mm and 2.5mm) |
JIS-82、JIS-87、JIS-94、JIS-01、JIS-13、ISO-84、ISO-97、DIN-90、ASME-95、GB-14